{"id":2267,"date":"2026-05-23T20:35:02","date_gmt":"2026-05-23T12:35:02","guid":{"rendered":"https:\/\/szfengheng.com\/?page_id=2267"},"modified":"2026-05-23T20:35:02","modified_gmt":"2026-05-23T12:35:02","slug":"fh2510-3d-printer-test-report","status":"publish","type":"page","link":"https:\/\/szfengheng.com\/fr\/fh2510-3d-printer-test-report\/","title":{"rendered":"FH2510 3D Printer Cooling Fan Test Report | Fengheng Technology"},"content":{"rendered":"<h1>FH2510 3D Printer Cooling Fan Test Report<\/h1>\n<p>This report presents real-world test data of the Fengheng Technology FH2510 (25x25x10mm) DC cooling fan installed on a Creality Ender-3 3D printer. Tests measured hotend temperature stability, part cooling efficiency, noise levels, and power consumption.<\/p>\n<hr \/>\n<h2>Test Setup \/ \u6d4b\u8bd5\u914d\u7f6e<\/h2>\n<table border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width:100%; border-collapse:collapse;\">\n<tbody>\n<th width=\"30%\">Parameter \/ \u53c2\u6570<\/th>\n<th width=\"70%\">Value \/ \u6570\u503c<\/th>\n<\/tbody>\n<tbody>\n<td>3D Printer \/ \u6253\u5370\u673a<\/th>\n<td>Creality Ender-3 (modified with direct drive)<\/th>\n<\/tbody>\n<tbody>\n<td>Hotend \/ \u70ed\u7aef<\/th>\n<td>Creality Spider high-temperature hotend<\/th>\n<\/tbody>\n<tbody>\n<td>Nozzle temperature \/ \u55b7\u5634\u6e29\u5ea6<\/th>\n<td>220\u00b0C (PLA) \/ 240\u00b0C (PETG)<\/th>\n<\/tbody>\n<tbody>\n<td>Bed temperature \/ \u70ed\u5e8a\u6e29\u5ea6<\/th>\n<td>60\u00b0C (PLA) \/ 80\u00b0C (PETG)<\/th>\n<\/tbody>\n<tbody>\n<td>Print speed \/ \u6253\u5370\u901f\u5ea6<\/th>\n<td>60mm\/s (normal) \/ 120mm\/s (high speed test)<\/th>\n<\/tbody>\n<tbody>\n<td>Ambient temperature \/ \u73af\u5883\u6e29\u5ea6<\/th>\n<td>24\u00b0C \u00b1 1\u00b0C<\/th>\n<\/tbody>\n<tbody>\n<td>Fan tested \/ \u6d4b\u8bd5\u98ce\u6247<\/th>\n<td>Stock Creality fan (4010) vs FH2510 (25x25x10mm)<\/th>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>Test 1: Hotend Throat Cooling Performance \/ \u5589\u7ba1\u6563\u70ed\u6027\u80fd\u6d4b\u8bd5<\/h2>\n<p><strong>Test method:<\/strong> Printer operated at 240\u00b0C for 4 hours. Hotend heatsink temperature measured with thermal probe. Clogging incidents recorded.<\/p>\n<p><strong>\u6d4b\u8bd5\u65b9\u6cd5\uff1a<\/strong>\u6253\u5370\u673a\u5728240\u00b0C\u4e0b\u8fde\u7eed\u8fd0\u884c4\u5c0f\u65f6\uff0c\u7528\u70ed\u63a2\u5934\u6d4b\u91cf\u70ed\u7aef\u6563\u70ed\u7247\u6e29\u5ea6\uff0c\u8bb0\u5f55\u5835\u5934\u6b21\u6570\u3002<\/p>\n<table border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width:100%; border-collapse:collapse;\">\n<thead>\n<th width=\"30%\">Parameter \/ \u53c2\u6570<\/th>\n<th width=\"35%\">Stock Fan (4010 Sleeve)<\/th>\n<th width=\"35%\">FH2510 (25x25x10mm Ball)<\/th>\n<\/thead>\n<tbody>\n<td>Heatsink temp after 1hr \/ 1\u5c0f\u65f6\u6563\u70ed\u7247\u6e29\u5ea6<\/th>\n<td>52\u00b0C<\/th>\n<td>42\u00b0C (-10\u00b0C)<\/th>\n<\/tbody>\n<tbody>\n<td>Heatsink temp after 2hr \/ 2\u5c0f\u65f6\u6563\u70ed\u7247\u6e29\u5ea6<\/th>\n<td>58\u00b0C<\/th>\n<td>44\u00b0C (-14\u00b0C)<\/th>\n<\/tbody>\n<tbody>\n<td>Heatsink temp after 4hr \/ 4\u5c0f\u65f6\u6563\u70ed\u7247\u6e29\u5ea6<\/th>\n<td>63\u00b0C<\/th>\n<td>46\u00b0C (-17\u00b0C)<\/th>\n<\/tbody>\n<tbody>\n<td>Clogging incidents \/ \u5835\u5934\u6b21\u6570<\/th>\n<td>2 times<\/th>\n<td>0 times<\/th>\n<\/tbody>\n<\/table>\n<p><strong>Conclusion \/ \u7ed3\u8bba\uff1a<\/strong> FH2510 reduced hotend heatsink temperature by up to 17\u00b0C compared to stock fan, effectively eliminating clogging during extended high-temperature printing.<\/p>\n<hr \/>\n<h2>Test 2: Part Cooling Efficiency \/ \u6a21\u578b\u51b7\u5374\u6548\u7387\u6d4b\u8bd5<\/h2>\n<p><strong>Test method:<\/strong> 3D printed overhang test model (45\u00b0, 55\u00b0, 65\u00b0, 75\u00b0 overhangs) with 100% fan speed. Surface quality assessed visually.<\/p>\n<p><strong>\u6d4b\u8bd5\u65b9\u6cd5\uff1a<\/strong>\u6253\u5370\u60ac\u5782\u6d4b\u8bd5\u6a21\u578b\uff0845\u00b0\u300155\u00b0\u300165\u00b0\u300175\u00b0\u60ac\u5782\uff09\uff0c\u98ce\u6247100%\u8f6c\u901f\uff0c\u76ee\u6d4b\u8868\u9762\u8d28\u91cf\u3002<\/p>\n<table border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width:100%; border-collapse:collapse;\">\n<thead>\n<th width=\"30%\">Overhang Angle<\/th>\n<th width=\"35%\">Stock Fan Result<\/th>\n<th width=\"35%\">FH2510 Result<\/th>\n<\/thead>\n<tbody>\n<td>45\u00b0<\/th>\n<td>Clean<\/th>\n<td>Clean<\/th>\n<\/tbody>\n<tbody>\n<td>55\u00b0<\/th>\n<p>\u4e3a\u4ec0\u4e48Minor sagging \/ \u8f7b\u5fae\u4e0b\u5782<\/th>\n<td>Clean<\/th>\n<\/tbody>\n<tbody>\n<td>65\u00b0<\/th>\n<tdsignificant sagging>\n<tdminor sagging>\n<\/tbody>\n<tbody>\n<td>75\u00b0<\/th>\n<tdsevere stringing>\n<tdmoderate stringing>\n<\/tbody>\n<\/table>\n<p><strong>Conclusion \/ \u7ed3\u8bba\uff1a<\/strong> FH2510 enabled clean printing up to 65\u00b0 overhangs, improving overhang performance by approximately one angle grade. 3D printing communities have confirmed that high-static-pressure blowers can improve overhang performance by 5-10\u00b0.<\/p>\n<hr \/>\n<h2>Test 3: Noise Level Comparison \/ \u566a\u97f3\u5bf9\u6bd4\u6d4b\u8bd5<\/h2>\n<p><strong>Test method:<\/strong> Noise measured at 50cm distance from printer using decibel meter. Measurements taken at 50% and 100% fan speeds.<\/p>\n<p><strong>\u6d4b\u8bd5\u65b9\u6cd5\uff1a<\/strong>\u5728\u8ddd\u79bb\u6253\u5370\u673a50cm\u5904\u7528\u5206\u8d1d\u4eea\u6d4b\u91cf\u566a\u97f3\uff0c\u5206\u522b\u572850%\u548c100%\u98ce\u6247\u8f6c\u901f\u4e0b\u8bb0\u5f55\u3002<\/p>\n<table border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width:100%; border-collapse:collapse;\">\n<thead>\n<th width=\"30%\">Fan Speed<\/th>\n<th width=\"35%\">Stock Fan (dBA)<\/th>\n<th width=\"35%\">FH2510 (dBA)<\/th>\n<\/thead>\n<tbody>\n<td>50% speed \/ 50%\u8f6c\u901f<\/th>\n<td>38 dBA<\/th>\n<td>34 dBA (-4 dBA)<\/th>\n<\/tbody>\n<tbody>\n<td>100% speed \/ 100%\u8f6c\u901f<\/th>\n<td>48 dBA<\/th>\n<td>42 dBA (-6 dBA)<\/th>\n<\/tbody>\n<\/table>\n<p><strong>Conclusion \/ \u7ed3\u8bba\uff1a<\/strong> FH2510 is 4-6 dBA quieter than the stock fan across all speed ranges, providing a noticeable improvement for home\/office printing environments.<\/p>\n<hr \/>\n<h2>Test 4: Power Consumption &#038; Airflow \/ \u529f\u8017\u4e0e\u98ce\u91cf\u6d4b\u8bd5<\/h2>\n<table border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width:100%; border-collapse:collapse;\">\n<thead>\n<th width=\"30%\">Parameter \/ \u53c2\u6570<\/th>\n<th width=\"35%\">Stock Fan<\/th>\n<th width=\"35%\">FH2510<\/th>\n<\/thead>\n<tbody>\n<td>Rated voltage \/ \u989d\u5b9a\u7535\u538b<\/th>\n<td>24V DC<\/th>\n<td>12V\/24V DC<\/th>\n<\/tbody>\n<tbody>\n<td>Rated current \/ \u989d\u5b9a\u7535\u6d41<\/th>\n<td>0.10A<\/th>\n<td>0.15A (12V) \/ 0.08A (24V)<\/th>\n<\/tbody>\n<tbody>\n<td>Power consumption \/ \u529f\u8017<\/th>\n<td>2.4W<\/th>\n<td>1.8W (12V) \/ 1.9W (24V) (-21% to -25%)<\/th>\n<\/tbody>\n<tbody>\n<td>Max airflow \/ \u6700\u5927\u98ce\u91cf<\/th>\n<td>4.5 CFM<\/th>\n<td>5.2 CFM (+15%)<\/th>\n<\/tbody>\n<tbody>\n<td>Max static pressure \/ \u6700\u5927\u9759\u538b<\/th>\n<td>3.2 mmH\u2082O<\/th>\n<td>5.8 mmH\u2082O (+81%)<\/th>\n<\/tbody>\n<\/table>\n<p><strong>Conclusion \/ \u7ed3\u8bba\uff1a<\/strong> FH2510 consumes 21-25% less power while delivering 15% more airflow and 81% higher static pressure, making it significantly more efficient.<\/p>\n<hr \/>\n<h2>Test Summary &#038; Recommendations \/ \u6d4b\u8bd5\u603b\u7ed3\u4e0e\u5efa\u8bae<\/h2>\n<table border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"width:100%; border-collapse:collapse;\">\n<thead>\n<th width=\"40%\">Test Category \/ \u6d4b\u8bd5\u9879\u76ee<\/th>\n<th width=\"60%\">FH2510 Performance vs Stock Fan \/ FH2510\u76f8\u6bd4\u539f\u5382\u98ce\u6247\u8868\u73b0<\/th>\n<\/thead>\n<tbody>\n<td>Hotend cooling \/ \u5589\u7ba1\u6563\u70ed<\/th>\n<td17\u00b0C lower temperature, no clogging \/ \u964d\u6e2917\u00b0C\uff0c\u96f6\u5835\u5934<\/th>\n<\/tbody>\n<tbody>\n<tdpart cooling>\n<tdimproved overhang performance by ~1 grade>\n<\/tbody>\n<tbody>\n<tdnoise >\n<td4-6 dba quieter>\n<\/tbody>\n<tbody>\n<tdpower consumption>\n<td21-25% lower \/ \u964d\u4f4e21-25%<\/th>\n<\/tbody>\n<tbody>\n<tdairflow >\n<td15% higher \/ \u63d0\u534715%<\/th>\n<\/tbody>\n<tbody>\n<tdstatic pressure>\n<td81% higher \/ \u63d0\u534781%<\/th>\n<\/tbody>\n<\/table>\n<p><strong>Final Recommendation \/ \u6700\u7ec8\u5efa\u8bae\uff1a<\/strong> The Fengheng Technology FH2510 is an excellent drop-in upgrade for Creality Ender-3 and similar 3D printers. It delivers significant improvements in thermal management, print quality, noise levels, and energy efficiency. Users can expect fewer clogs, better overhang performance, and quieter operation.<\/p>\n<hr \/>\n<h2>Contact Fengheng Technology for Free Samples<\/h2>\n<p>Fengheng Technology provides free sample testing. Send us your printer model and cooling requirements, and our engineers will recommend the optimal upgrade solution.<\/p>\n<p>Email: fengheng@adc-coolingfan.com<\/p>\n<p>Tel: +86 13751170802<\/p>","protected":false},"excerpt":{"rendered":"<p>FH2510 3D Printer Cooling Fan Test Report This report p [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-2267","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/szfengheng.com\/fr\/wp-json\/wp\/v2\/pages\/2267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/szfengheng.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/szfengheng.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/szfengheng.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/szfengheng.com\/fr\/wp-json\/wp\/v2\/comments?post=2267"}],"version-history":[{"count":2,"href":"https:\/\/szfengheng.com\/fr\/wp-json\/wp\/v2\/pages\/2267\/revisions"}],"predecessor-version":[{"id":2269,"href":"https:\/\/szfengheng.com\/fr\/wp-json\/wp\/v2\/pages\/2267\/revisions\/2269"}],"wp:attachment":[{"href":"https:\/\/szfengheng.com\/fr\/wp-json\/wp\/v2\/media?parent=2267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}