{"id":1709,"date":"2026-05-21T21:41:39","date_gmt":"2026-05-21T13:41:39","guid":{"rendered":"https:\/\/szfengheng.com\/?page_id=1709"},"modified":"2026-05-22T14:22:48","modified_gmt":"2026-05-22T06:22:48","slug":"security-surveillance","status":"publish","type":"page","link":"https:\/\/szfengheng.com\/en\/security-surveillance\/","title":{"rendered":"Security Monitoring Heat Dissipation Solution | Fengheng Technology"},"content":{"rendered":"<h1>Security Monitoring Heat Dissipation Solution | Fengheng Technology<\/h1>\n<p>Fengheng Technology provides professional heat dissipation solutions for the security and surveillance industry. Its products are widely used in network cameras, PTZ cameras, DVR\/NVR hard disk recorders, access control controllers, facial recognition terminals and other equipment, meeting the stringent requirements of outdoor all-weather operation for waterproof and dustproof, wide temperature range and low noise.<\/p>\n<hr \/>\n<h2>I. Four Core Pain Points of Heat Dissipation in Security Monitoring Systems<\/h2>\n<h3>Pain Point 1: High requirements for waterproofing and dustproofing of outdoor equipment<\/h3>\n<p><strong>Phenomenon:<\/strong>Outdoor cameras and PTZ cameras may malfunction after water or dust gets into their fans, causing the equipment to overheat and crash.<\/p>\n<p><strong>root cause:<\/strong>Use a regular fan instead of an IP protection-rated fan.<\/p>\n<p><strong>Industry Standards:<\/strong>Outdoor security equipment typically requires IP66, IP67 or higher protection ratings.<\/p>\n<h3>Pain Point 2: Strict requirements for adaptability to wide temperature environments<\/h3>\n<p><strong>Phenomenon:<\/strong>In northern winters, fans cannot start when temperatures drop below -30\u00b0C, and in southern summers, they shut down when temperatures exceed 60\u00b0C.<\/p>\n<p><strong>root cause:<\/strong>The fan uses ordinary lubricating oil, which solidifies at low temperatures and evaporates at high temperatures.<\/p>\n<p><strong>Industry data:<\/strong>Security equipment typically requires an operating temperature range of -30\u2103 to +70\u2103.<\/p>\n<h3>Pain Point 3: High reliability is required for continuous operation 24\/7<\/h3>\n<p><strong>Phenomenon:<\/strong>The fan stops working after 1-2 years of operation, causing the equipment to overheat and be damaged.<\/p>\n<p><strong>root cause:<\/strong>Cheap oil-bearing fans have a lifespan of only 10,000 to 20,000 hours<\/p>\n<p><strong>Industry feedback:<\/strong>The contractor stated that &quot;camera fan failure is one of the main reasons for the return for repairs.&quot;<\/p>\n<h3>Pain Point 4: The requirement for low noise in quiet environments<\/h3>\n<p><strong>Phenomenon:<\/strong>The noise from the fans of indoor monitoring equipment (such as access control and facial recognition terminals) can negatively impact the user experience.<\/p>\n<p><strong>root cause:<\/strong>Small fans require high speeds to achieve the desired airflow, which in turn leads to high noise levels.<\/p>\n<p><strong>User feedback:<\/strong>Users of access control equipment in office buildings are complaining that &quot;the fans are too noisy.&quot;<\/p>\n<hr \/>\n<h2>II. Comparison Table of Fan Solutions for Mainstream Security Monitoring Equipment<\/h2>\n<table border=\"1\" cellpadding=\"8\" cellspacing=\"0\">\n<thead>\n<th>Equipment type<\/th>\n<th>Brand\/Model<\/th>\n<th>Fan position<\/th>\n<th>Original factory specifications<\/th>\n<th>Frequently Asked Questions<\/th>\n<th>Fengheng Upgrade Recommendation<\/th>\n<th>Reasons for upgrading<\/th>\n<\/thead>\n<tbody>\n<td>Network Camera \/ IP Camera<\/td>\n<td>Hikvision, Dahua, Uniview<\/td>\n<td>Heat dissipation from the casing<\/td>\n<td>30x30x10mm \/ 40x40x10mm 12V<\/td>\n<td>Outdoor waterproofing failed<\/td>\n<td>FH3010 \/ FH4010 IP67 Wide Temperature Version<\/td>\n<td>IP67 protection, operating temperature -30\u2103 to +70\u2103<\/td>\n<\/tr>\n<tr>\n<td>PTZ camera<\/td>\n<td>Hikvision, Dahua, Samsung<\/td>\n<td>gimbal interior<\/td>\n<td>40x40x28mm \/ 50x50x15mm 12V<\/td>\n<td>Prolonged rotation and vibration cause bearing damage<\/td>\n<td>FH4028 \/ FH5015 Dual Ball Bearing Anti-vibration Version<\/td>\n<td>Seismic design extends service life to 50,000 hours<\/td>\n<\/tr>\n<tr>\n<td>DVR\/NVR hard disk recorder<\/td>\n<td>Hikvision, Dahua, TP-LINK<\/td>\n<td>Rear exhaust fan<\/td>\n<td>50x50x15mm \/ 60x60x25mm 12V<\/td>\n<td>The fan stops running after 1-2 years of 7x24-hour operation.<\/td>\n<td>FH5015 \/ FH6025 Double Ball Version<\/td>\n<td>Lifespan of 50,000 hours, supports continuous operation<\/td>\n<\/tr>\n<tr>\n<td>Access control controller\/facial recognition terminal<\/td>\n<td>Supcon Smart, Entropy Technology, Hikvision<\/td>\n<td>Motherboard cooling<\/td>\n<td>25x25x10mm \/ 30x30x10mm 5V\/12V<\/td>\n<td>Noise sensitivity in indoor settings<\/td>\n<td>FH2510 \/ FH3010 Hydraulic Bearing Silent Version<\/td>\n<td>noise&lt;20dBA<\/td>\n<\/tr>\n<tr>\n<td>Smart door locks\/video doorbells<\/td>\n<td>Xiaomi, Deshman, Kaadas<\/td>\n<td>Internal heat dissipation<\/td>\n<td>25x25x10mm 5V<\/td>\n<td>Limited selection of ultra-miniature fans<\/td>\n<td>FH2507 \/ FH2510 Miniature Ball Bearing<\/td>\n<td>Designed specifically for smart door locks, ultra-thin and low power consumption<\/td>\n<\/tr>\n<tr>\n<td>Security power supply\/POE switch<\/td>\n<td>Huawei, Ruijie, TP-LINK<\/td>\n<td>Heat dissipation from the casing<\/td>\n<td>40x40x10mm \/ 40x40x20mm 12V<\/td>\n<td>Insufficient heat dissipation under high load<\/td>\n<td>FH4010 \/ FH4020 High Airflow Version<\/td>\n<td>Air volume increased 25%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>III. Quick Reference Table for Security Monitoring Heat Dissipation Solutions<\/h2>\n<table border=\"1\" cellpadding=\"8\" cellspacing=\"0\">\n<thead>\n<th>Equipment type<\/th>\n<th>Heat dissipation requirements<\/th>\n<th>Recommended Model<\/th>\n<th>Core parameters<\/th>\n<\/thead>\n<tbody>\n<tr>\n<td>Outdoor camera\/PTZ camera<\/td>\n<td>IP-protected heat dissipation<\/td>\n<td>FH3010 \/ FH4010 \/ FH5015 IP67<\/td>\n<td>12V, IP67, -30\u2103 to +70\u2103<\/td>\n<\/tr>\n<tr>\n<td>DVR\/NVR<\/td>\n<td>Continuous operation heat dissipation<\/td>\n<td>FH5015 \/ FH6025 Double Ball<\/td>\n<td>12V, dual ball bearing, 50,000 hours<\/td>\n<\/tr>\n<tr>\n<td>Access control\/facial recognition<\/td>\n<td>Silent heat dissipation<\/td>\n<td>FH2510 \/ FH3010 Hydraulic Bearings<\/td>\n<td>5V\/12V, hydraulic bearing&lt;20dBA<\/td>\n<\/tr>\n<tr>\n<td>Smart door lock<\/td>\n<td>Ultra-miniature heat dissipation<\/td>\n<td>FH2507 \/ FH2510 Miniature<\/td>\n<td>5V, ultra-thin design, low power consumption<\/td>\n<\/tr>\n<tr>\n<td>PoE Switch\/Security Power Supply<\/td>\n<td>Chassis ventilation<\/td>\n<td>FH4010 \/ FH4020 High Airflow<\/td>\n<td>12V, high airflow, long lifespan<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<hr \/>\n<h2>IV. Key Considerations for Heat Dissipation Design in Security Monitoring Systems<\/h2>\n<p><strong>1. Protection level selection<\/strong><\/p>\n<ul>\n<li>Outdoor equipment: IP66\/IP67, completely dustproof, can withstand heavy rain.<\/li>\n<li>Semi-outdoor equipment: IP54\/IP55, dustproof and splashproof<\/li>\n<li>Indoor equipment: No special protection requirements, quiet operation is preferred.<\/li>\n<\/ul>\n<p><strong>2. Wide temperature range requirements<\/strong><\/p>\n<ul>\n<li>Northern regions: Requires support for starting at -30\u2103 and the use of special lubricating oil.<\/li>\n<li>Southern regions: Must be able to operate at temperatures up to +70\u2103, using high-temperature resistant materials.<\/li>\n<li>Large temperature difference between day and night: condensation protection needs to be considered.<\/li>\n<\/ul>\n<p><strong>3. Reliability Requirements<\/strong><\/p>\n<ul>\n<li>Security equipment typically requires continuous operation 24\/7.<\/li>\n<li>We recommend a dual ball bearing fan with a lifespan of \u226550,000 hours.<\/li>\n<li>It is recommended that critical equipment support fault detection (RD signal).<\/li>\n<\/ul>\n<hr \/>\n<h2>V. Frequently Asked Questions (FAQ)<\/h2>\n<h3>Q1: What protection level is required for the fan of an outdoor camera?<\/h3>\n<p>A: At least IP66, IP67 is recommended. IP67 is completely dustproof and can be submerged in 1 meter of water for 30 minutes without damage.<\/p>\n<h3>Q2: What should I do if my fan won&#039;t start in the low temperatures of northern winters?<\/h3>\n<p>A: Select a wide-temperature model (-30\u2103~+70\u2103) and use special lubricating oil to ensure it does not solidify at low temperatures.<\/p>\n<h3>Q3: How often do the fans in security equipment typically need to be replaced?<\/h3>\n<p>A: Original equipment manufacturer (OEM) oil-impregnated bearing fans typically last 1-2 years. Fengheng dual ball bearing fans can last 5-7 years, matching the lifespan of the equipment.<\/p>\n<h3>Q4: How to solve the problem of loud fan noise in indoor access control equipment?<\/h3>\n<p>A: Choose a hydraulic bearing silent fan. The noise level of the Fengheng FH2510\/FH3010 hydraulic bearing series can be controlled below 20dBA.<\/p>\n<h3>Q5: Do you support sample testing?<\/h3>\n<p>A: Free sample testing is available. We can provide original fan specifications and help you find the right upgrade solution.<\/p>\n<hr \/>\n<h2>VI. Contact us to obtain samples<\/h2>\n<p>\u90ae\u7bb1\uff1afengheng@adc-coolingfan.com<\/p>\n<p>Telephone: +86 13751170802<\/p>\n<p>Official website: www.szfengheng.com<\/p>\n<p>Security equipment manufacturers, engineering companies, and system integrators are welcome to inquire about cooperation.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u5b89\u9632\u76d1\u63a7\u6563\u70ed\u89e3\u51b3\u65b9\u6848 | \u98ce\u6052\u79d1\u6280 \u98ce\u6052\u79d1\u6280\u4e3a\u5b89\u9632\u76d1\u63a7\u884c\u4e1a\u63d0\u4f9b\u4e13\u4e1a\u6563\u70ed\u89e3\u51b3\u65b9\u6848\uff0c\u4ea7\u54c1\u5e7f\u6cdb\u5e94\u7528\u4e8e\u7f51\u7edc\u6444\u50cf\u673a\u3001\u7403\u673a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-1709","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/szfengheng.com\/en\/wp-json\/wp\/v2\/pages\/1709","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/szfengheng.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/szfengheng.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/szfengheng.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/szfengheng.com\/en\/wp-json\/wp\/v2\/comments?post=1709"}],"version-history":[{"count":2,"href":"https:\/\/szfengheng.com\/en\/wp-json\/wp\/v2\/pages\/1709\/revisions"}],"predecessor-version":[{"id":1711,"href":"https:\/\/szfengheng.com\/en\/wp-json\/wp\/v2\/pages\/1709\/revisions\/1711"}],"wp:attachment":[{"href":"https:\/\/szfengheng.com\/en\/wp-json\/wp\/v2\/media?parent=1709"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}